Deflux System MICROCLEANER ECO®

Deflux system for electronic circuits and components. Excellent cleaning performance, environmentally friendly and cost effective all at the same time

 

High cleanability and low VOC


Better cleaning performance yet less VOC emission (70% water contained) compared to solvent based cleaning system.


Built-in distiller


Closed system without waste-water using no water for rinsing.


Non-Rinse One-liquid cleaning system


Only one cleaning chemical is easy to manage. One-liquid system enables easy and compact operation, 75% in size compared to our conventional equipment.

System flow

Specification

【General property】

MICOCLEAN ECO-3002U (undiluted) Microclinic ECO-3002U (three-fold dilution by water)
Specific gravity 0.88
Boiling point 160℃ or more 100℃ or more
Flash point 62℃ 94℃
ODP (Ozone Depletion Potential) 0 0
Surface tension Oil phase: 29 mN/m water phase: 29 mN/m
UN Class N/A N/A
UN No N/A N/A


【Cleaning property】

Company A
Lead-free solder paste
Sn-3Ag-0.5Cu
Company B
Lead-free solder paste
Sn-3Ag-0.5Cu
C社
Halogen-free solder paste
Sn-3Ag-0.5Cu
Before cleaning
(After reflow)
MICROCLEAN
ECO-3002U
(Three-fold dilution by water)
60° C/10min
Stirring
Hydrocarbon-based cleaning chemical
Ultrasound for 40° C/10min

【MICROCLEANER ECO Specifications】

Model MC2HD−2PE MC2HD−5PE
W×D×H 1,253×800×1,290mm 2,300×1,200×1,800mm
Weight About 200kg Approx. 400kg
Power supply Three-phase 200V 20A Three-phase 200V 61A
Required water supply
(Distiller)
Below 35°C, Over 10L/min Below 35°C, Over 20L/min
Cleaning capacity A5 size approx. 25 panels/hr A4 size approx. 80 panels/hr
Tank size (opening) W100 mm x D300mm W200 mm by D500mm
Applicable panel size MAX. 200×165mm MAX. 370×345mm
First tank (pre-cleaning) Liquid amount: approx. 9L
Circulation cleaning and heating temperature control
Liquid amount: approx. 50L
Circulation cleaning and heating temperature control
Second tank (cleaning) Liquid amount: approx. 9L
Circulation cleaning and heating temperature control
Liquid amount: approx. 50L
Circulation cleaning and heating temperature control
Third tank (drying) Valid volume: approx. 9L
Hot air circulation, heating temperature control
Valid volume: approx. 50L
Hot air circulation, heating temperature control
Distiller (cleaning chemical) Distillation with built-in distiller (First tank → Second tanks)
Maximum amount of flux brought into the first tank: 20 g/hr
Distillation with built-in distiller (First tank → Second tanks)
Maximum amount of flux brought into the first tank: 50 g/hr
Required supplement Exhaustion facility
Cooling water supply facility
Exhaustion facility
Cooling water supply facility

Product inquiry


Return to Products List

Contact Us

  • Inquiry form